Barrier Film Metallised, Broad Seal, High Hot Tack & Barrier
HST-1(HSB) MO T095
Structure
Aluminium layer
Modified treated, OPP layer
OPP core
Un-treated, LTS, HT modified OPP layer
Description

It is a co-extruded, one side metallised and other side low heat sealable & high hot tack Bi-axially Oriented Polypropylene film.

Features
  • Excellent performance in VFFS & HFFS machine
  • Good metal adhesion to film
  • Very good barrier to moisture and light
  • Very good gas barrier
  • High heat seal strength
  • High hot tack strength
  • Broad seal range
Applications
  • As a laminate for snack food, bakery & confectionery packaging application
Typical values
Properties Ref. Units ASTM#/ Test Method HST-1(HSB) MO T095
Physical Data
Average Thickness      Micron D-374-C1518 20
Gauge60 72 80
Mils0.6 0.70 0.78
Thickness Variation      %(±)      3
Density      g/cc      0.905
Average substance      g/m²      13.5716.318.1
Kinetic COF NM-NM      0.25-0.40
Yield      m²/Kg D-432173.761.355.24
in²/lb518164309838837
Optical Data
Optical Density      CTM2.2
Mechanical Data
Tensile Strength MD kg/cm² D-8821300-1500
TD2600-2800
Elongation MD % D-882150-190
TD 40-70
Thermal Data
Shrinkage
(120⁰C/248 ⁰F,5 min)
MD % D-12043.0-5.0
TD 1.0-3.0
Heat Seal Range      °C CTM90-145
Heat Seal Strength (min.)      g/²5 mm CTM>500
Hot Tack      g/²5 mm ASTM F-1921>250
Seal Initiation Temp.      °C/°F CTM95/203
SIT Variation (±)      °C/°F CTM2
Barrier Data
MVTR (38⁰C, 90% RH)      g/m²/day F-1249<0.25
MVTR (100 °F,90%RH)      g/100 in²/day F-1249<0.01
OTR (23⁰C, 0% RH)      cc/m²/day D-3985<30
OTR (73⁰F, 0% RH)      cc/100 in²/day D-3985<1.93
CTM : Cosmo Test Method MD : Machine Direction TD : Transverse Direction MT : Metal UT: Untreated Side NM: Non Metallised
Disclaimer : The information provided above is based on COSMO FILMS LTD's conclusive tests, which are indicative only and provided as guidelines.They do not constitute a guarantee of any specific product attributes or the suitability of products for specific applications
Storage condition : Storage temperature to be maintained 25 Deg.C (+/-5 Deg C) & relative humidity 55% (+/-5%)  to avoid accelerated reduction of surface treatment level.  
Note : Treatment values in metalized films tend to decay over a period of time during transportation & subjected to storage conditions, hence it is recommended to check the treatment prior to processing & if reduction is observed then go for online treatment, high adhesive GSM & a suitable primer may be applied.